Electromagnetic Compatibility (EMC) and Immunity tests and measurements

Since 2008 the High Voltage Laboratory is accredited according to ELOT ΕΝ ISO/IEC 17025 for a large variety of Electromagnetic Compatibility (EMC) tests and measurements, associated with most of the modern commercial and industrial Product Standards, continuously investing in the up-to-date scientific training of the personnel and monitoring the ever-changing requirements of International, European and National Standardization

  • Measurement of conducted emissions (Standards ELOT ΕΝ 55032, ΕΝ 55014-1, EN 55015, EN 55011 etc) in power ports of equipment in the frequency range from 9kHz up to 30MHz, which aims to certify that neighboring apparatus is not affected by the disturbances that are conducted through the interconnecting cables of the equipment.

agomenes diataraxes
  • Measurement of radiated emissions (Standards ELOT ΕΝ 55032, ELOT ΕΝ 55014-1, ELOT EN 55015, ELOT EN 55011 etc) in the frequency range from 150kHz up to 18GHz, which aims to certify that neighboring apparatus is not affected by the disturbances emitted in terms of electromagnetic field from the enclosure of the equipment.

  • Measurement of discontinuous disturbances (Std ELOT ΕΝ 55014-1): transient conducted emissions generated by equipment with main functions that are carried out with motors and switching devices.

diakoptomones diataraxes
  • Measurement of disturbance power (Standard ELOT ΕΝ 55014-1): measurement of continuous generated electromagnetic power disturbance in the frequency range from 30MHz up to 300MHz.

diataraxes isxios
  • Measurement of the current harmonics (ELOT ΕΝ 61000-3-2) emitted by the equipment to its power supply network, thus contributing to maintaining the power quality of the electricity network.

armonikes
  • Measurement of voltage fluctuations and flicker (Standard ELOT ΕΝ 61000-3-3) which aims to certify that the equipment under test does not cause variations in its voltage supply.

diakimansis tasis
  • Immunity to Electrostatic Discharge test (ELOT ΕΝ 61000-4-2), aiming to certify that the equipment will not be disturbed by electrostatic discharges generated from other charged devices or operators.

hlektrostatikh ekfortosi
  • Immunity to RF Electromagnetic Radiated Field test (Standard ELOT ΕΝ 61000-4-3), which aims to certify that the equipment will operate properly in an environment with radiated radio-disturbances.

atrosia se pedio
  • Immunity to Bursts test (Standard ELOT ΕΝ 61000-4-4), which aims to certify that the performance of the equipment will not deteriorate in the presence of conducted disturbances caused by fast switching operations of contacts and loads.

grigora metavatika fenomena
  • Immunity to Surges test (Standard ELOT ΕΝ 61000-4-5), which aims to certify that the equipment will continue to perform properly when subjected to overvoltages or overcurrents caused e.g. by a lightning strike.

IMG_7270
  • Immunity to Conducted Electromagnetic Field test (ELOT ΕΝ 61000-4-6), which aims to certify that the performance of the equipment will not deteriorate in the presence of conducted RF disturbances.

atrosia se agomenes
  • Immunity to Power Frequency Magnetic Field test (Standard ELOT ΕΝ 61000-4-8), which aims to certify that the equipment will continue to perform properly in the presence of power frequency magnetic field.

atrosia se magnitiko pedio
  • Immunity to Voltage Dips and Short Interruptions test (Standard ELOT ΕΝ 61000-4-11), which aims to certify that the equipment will not be affected by variations or interruptions of its power supply.

vithisis tasis
  • Immunity to transient phenomena test on power lines and immunity test (Standards ISO 7637-1, 7637-2, 7637-3, ISO 16750-1, 16750-2) to power supply interruption for on board vehicle equipment, which aims to certify that the equipment in the environment of a vehicle will not be affected by transient phenomena and specific types of variations of its power supply.

atrosia se metavatika

We will be very happy to hear from you!

Please do not hesitate to contact us for any information you need.

    [contact-form-7 404 "Not Found"]